LED - Adaptation
LED-ADAPT
▪ Operating voltage: 12V nominal
▪ Input: open cable ends
▪ Output: open cable ends
- Operation voltage: 12V nominal
- Output current: 0.8A (Over current protection time delay 1...2000s !)
- Connection input: sheathed cable 8x1mm², open cable ends
- Connection output: sheathed cable 8x1mm², open cable ends
- Load imitation: 2x17 W (direction), 2x4W (rear lamp), 1x34W (stop light) 1x17W (fog lamp), 1x17W (reversing lamp)
- Cable length input: app. 3,5m
- Cable length output: app. 1,2m
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 280 x 70 x 25mm without cable outlet
- Mass: app. 1,58 kg
- Failure monitor LEDs: 20mA (direction) 3mA (rear lamp) 8mA (stop light) 8mA (fog lamp) 20mA (reversing lamp)
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thikness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT (Bypass)
▪ Operating voltage: 24V
▪ Input: open cable ends
▪ Output: open cable ends
- Operation voltage: 24V nominal
- Output current: max. 8A each line (bypass on)
- Connection input: sheathed cable 7x1+1x2,5mm², open cable ends
- Connection output: sheathed cable 7x1+1x2,5mm², open cable ends
- Load imitation: 2x17 W (direction), 2x4W (rear lamp), 1x34W (stop light) 1x17W (fog lamp), 1x17W (reversing lamp)
- Cable length input: app. 3500mm
- Cable length output: app. 1200mm
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 280 x 70 x 25mm
- Mass: app. 1,62 kg
- Failure monitor LEDs: 24mA (direction), 860mA bypass, 6,5mA (rear lamps), 330mA bypass, 9mA (stop light), 1510mA bypass, 9,5mA (rear fog lamp), 860mA bypass, 24mA (refersing light), 860mA bypass
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thikness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT
▪ 24V-resistor replacement load for LED lights in a trailer, single cable solution
- Operation voltage: 24V nominal
- Output current: direction 0.4A (Over current protection time delay 1…2000s!)
- Connection: hose line 5 x 1mm², length 0.25m, ins. 6.3mm blade receptacle
- Load imitation: 2x17 W (direction)
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (Vollverguss)
- Dimensions: 120 x 70 x 25mm
- Mass: app. 0,35 kg
- Failure monitor LEDs: 20mA (direction)
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thickness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT
▪ Operating voltage: 12V nominal
▪ as ballast for LED direction indicators
▪ operates right and left turn signals
- Operation voltage: 12V nominal
- Output current: max. 0.4A (direction) (Over current protection time delay 1...2000s!)
- Connection: hose line 5x1mm², ins. 6.3mm blade receptacle
- Load imitation: 2x17W (direction)
- Cable length: app. 250mm
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 120 x 70 x 25mm
- Mass: app. 0,41 kg
- Failure monitor LEDs: 20mA (direction)
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thickness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT (Bypass)
▪ Operating voltage: 12V
▪ Input: open cable end
▪ Output: open cable end
- Operation voltage: 12V nominal
- Output current: max. 8A each line (bypass on)
- Connection input: sheathed cable 7x1+1x2,5mm², open cable ends
- Connection output: sheathed cable 7x1+1x2,5mm², open cable ends
- Load imitation: 2x17 W (direction), 2x4W (rear lamp), 1x34W (stop light) 1x17W (fog lamp), 1x17W (reversing lamp)
- Cable length input: app. 3500mm
- Cable length output: app. 1200mm
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 280 x 70 x 25mm
- Mass: app. 1,62 kg
- Failure monitor LEDs: 24mA (direction), 860mA bypass, 6,5mA (rear lamps), 600mA bypass, 9mA (stop light), 1510mA bypass, 9,5mA (rear fog lamp), 860mA bypass, 24mA (refersing light), 860mA bypass
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thikness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT
▪ Operating voltage: 24V nominal
▪ Input: open cable end
▪ Output: open cable end
- Operation voltage: 24V nominal
- Output current: 0.4A (Over current protection time delay 1...2000s !)
- Connection input: sheathed cable 8x1mm², open cable ends
- Connection output: sheathed cable 8x1mm², open cable ends
- Load imitation: 2x17 W (direction), 2x4W (rear lamp), 1x34W (stop light) 1x17W (fog lamp), 1x17W (reversing lamp)
- Cable length input: app. 3500mm
- Cable length output: app. 1200mm
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 280 x 70 x 25mm without cable outlet
- Mass: app. 1,58 kg
- Failure monitor LEDs: 20mA (direction) 3mA (rear lamp) 8mA (stop light) 8mA (fog lamp) 20mA (reversing lamp)
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thikness) or on chassis frame
- Approval: E1 10R-046841
LED-ADAPT
▪ Operating voltage: 12V
▪ Input: 12V 13-pol plug
▪ Output: 12V 13-pol socket
- Operation voltage: 12V nominal
- Output current: 0.8A (Over current protection time delay 1...2000s !)
- Connection input: male connector 13 pin 12V ISO'11446
- Connection output: female socket with flap cover 13 pin 12V ISO'11446
- Load imitation: 2x4W (rear lamps), 1x34W (stop light) 1x17W (fog lamp), 1x17W (reversing lamp)
- Cable length input: app. 3300mm
- Cable length output: app. 600mm
- Temperature range: -40 ... +75°C
- Electrical protection: overcurrent, overtemperature, reverse polarity
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 280 x 70 x 25mm without cable outlet
- Mass: app. 2,80 kg
- Failure monitor LEDs: 3mA (rear lamp) 8mA (stop light) 8mA (fog lamp) 20mA (reversing lamp)
- Mounting rule: cooling plate 8dm² (aluminium sheet 1.5mm thickness) or on chassis frame, lamp configuration only 2 x incandescent lamps + 5xLED(+0...10W)
- Approval: E1 10R-046841
Flash Prevent
▪ Prevents flashing of LED lamps
▪ LED failure detection stays in function
▪ Easy installation ahead of to the LED
▪ possible to install inside the lamp housing
- Operation voltage: 12V nominal
- Output current: LED (max 0.4A)
- Connection input: strand with open cable ends
- Load imitation: within 0-50ms cold filament
- Cable length input: app. 300mm
- Temperature range: -40 … +75°C
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 40 x 18 x 15 mm without cable outlet
- Mass: app. 0,04 kg
- Failure monitor LEDs: integrated
- Approval: CE
Flash Prevent 24 Volt
▪ Prevents flashing of LED lamps
▪ LED failure detection stays in function
▪ Easy installation ahead of to the LED
▪ possible to install inside the lamp housing
- Operation voltage: 24V nominal
- Output current: LED (max 0.4A)
- Connection input: strand with open cable ends
- Load imitation: within 0-50ms cold filament
- Cable length input: app. 300mm
- Temperature range: -40 … +75°C
- Mechanical protection: IP 6K9K (entirely sealed)
- Dimensions: 40 x 18 x 15 mm without cable outlet
- Mass: app. 0,04 kg Failure monitor LEDs
- Failure monitor LEDs: integrated
- Approval: CE